DRT Characteristic Peaks for PEM Electrolyzers

Polarization ID without ECM

A relaxation-time-distribution-based impedance spectroscopy analysis for PEM electrolyzers that identifies polarization contributions from water/gas diffusion, HER/OER, and proton transfer without requiring an equivalent circuit model.

Li, Yangyang · Yayang, Jiang · Dang, Jian · Deng, Xintao · Liu, Biao · Ma, Jugang · Yang, Fuyuan · Ouyang, Minggao · Shen, Xiaojun

Chemical Engineering Journal 2023

Specifications

proton transfer are
{'zh': '60', 'en': '60'} Hz

Advantages

Three characteristic peaks represent the main polarization processes in the hydrogen production system

Optimal regularization parameter is 0.01 for different current and temperature