Controls Temperature Rise and Uniformity
For battery thermal management, compares coolant temperature control strategies to trade off temperature rise and uniformity under varying ambient temperatures.
Xu, Qiang · Jiacai, Zhang · Xinyu, Li · Kang, Zhang · Xue, Li · Bei, Shaoyi · Kai, Zhu · Wang, Xiaochun · Zheng, Keqing · Li, Li
Journal of Energy Storage 2026
At ambient temperatures of 35°C and 40°C, the fixed temperature difference strategy (Strategy 3) avoids the peaks in temperature difference seen with the fixed inlet temperature strategy (Strategy 1), offering a compromise in uniformity.
At 25°C ambient temperature, the fixed inlet temperature strategy (Strategy 1) achieves the best temperature rise control.
The derived conclusions are applicable under various coolant velocities, channel numbers and flow direction layouts.