AHSS Interface Oxide Layer

Reveals adhesion failure origin

Quasi-in-situ analysis and first-principles calculations identify continuous Mn/Si external oxides and pores within the SiO2 layer as key causes of adhesion failure at the reduced iron/substrate interface of AHSS.

Jin, Xinyan · Guangxin, Wu

Materials Characterization 2023

Advantages

SiO2/(011)Fe interface has highest binding energy, most prone to cracking (first-principles prediction)

Actual crack initiates and propagates inside amorphous SiO2 layer, not along SiO2/Fe interface

SiO2 layer contains numerous pores, serving as actual crack initiation sites