Controllable HIC susceptibility
Hydrogen-induced cracking susceptibility can be minimized by tuning the alternating loading frequency, with a minimum at 1.5 Hz.
Li, Hao · Huang, Feng · Peng, Zhang · Cejun, Wang · Hu, Qian · Fan, Lixia · Chao, Liu · Liu, Zhiyong · Li, Xiaogang · Peng, Zhixian · Jing, Liu
Corrosion Science 2026
HIC behavior is attributed to the coupling effect between hydrogen and dislocations