Hydrogen-Embrittlement Bridge Cable Steel

76% Longer Life with Anodic Protection

Anodic current suppresses hydrogen uptake and extends stress corrosion fracture time without altering mechanical properties.

Zhang, Zeling · Wang, Linfeng · Wenxian, Huang · Min, Xuegang · Luo, Guoqiang · Wang, Haibin · Zhou, Lichu · Xie, Zonghan · Fang, Feng

International Journal of Hydrogen Energy 2025

Specifications

阳极电流
{'zh': '50', 'en': ''} A/m²

Advantages

Fracture time extended from 26.1 h to 46.1 h

Corrosion potential of HE-type SCC does not change with time

Tensile strength and diameter almost same as before corrosion